Essatech is a fire suppression company in Hyderabad with a team in Gachibowli. For the category overview, see our fire suppression systems hub, and for plain definitions read the guide to types of fire suppression systems.
A sprinkler floods a floor, and that is the wrong answer for a switchgear room or a data hall. An automatic fire suppression system in Hyderabad protects one defined hazard with an agent made for it. Our engineers design the detection, release and agent store as one unit.
Systems we design, fit and service
The table lists each fire suppression system in Hyderabad that we fit, with the space it suits and a link to its page.
- System
- Clean agent (FM200 or FK-5-1-12)
- Suits
- Server rooms, control rooms, archives
- Page
- [Clean agent](/clean-agent-fire-suppression-system-hyderabad)
- System
- Inert gas (IG-541, IG-55)
- Suits
- Data halls and rooms where people work
- Page
- [Inert gas](/inert-gas-fire-suppression-system-hyderabad)
- System
- CO2 flooding
- Suits
- DG rooms, cable galleries, paint booths
- Page
- [CO2 flooding](/co2-flooding-system-hyderabad)
- System
- Condensed aerosol
- Suits
- Panels, cable rooms, engine bays
- Page
- [Aerosol](/aerosol-fire-suppression-system-hyderabad)
- System
- Tube based direct and indirect
- Suits
- Cabinets, racks, CNC machines
- Page
- [Tube based](/tube-based-fire-suppression-system-hyderabad)
- System
- Wet chemical kitchen hood
- Suits
- Restaurants, hotels, canteens
- Page
- [Kitchen hood](/kitchen-hood-fire-suppression-system-hyderabad)
- System
- Water mist
- Suits
- Hotels, hospitals, tunnels and plant rooms
- Page
- [Water mist](/water-mist-system-hyderabad)
- System
- Lithium battery protection
- Suits
- UPS battery rooms, storage, EV charging
- Page
- [Lithium battery](/lithium-battery-fire-suppression-hyderabad)
Gas and room flooding systems
A gas suppression system in Hyderabad fills a sealed room with an agent that stops the fire without water. Our FM200 gas suppression and Novec 1230 fire suppression pages cover the clean agents. HFC-227ea is sold as FM200, and FK-5-1-12 is the agent sold as Novec 1230.
Where staff work inside the room, read our page on manned area fire suppression. Where nobody enters, CO2 is a sound choice, with lock-off and a time delay.
Local protection for machines, cabinets and kitchens
Not every hazard needs a flooded room. A pressurised polymer tube inside a panel bursts at the fire point and discharges the agent onto it, with no power needed. Condensed aerosol generators suit small enclosed spaces.
Commercial kitchens use a wet chemical system with nozzles over each appliance and an automatic gas shut-off.
How to choose the right system
Four questions decide the fire suppression system in Hyderabad that fits a room.
- Is the room occupied when it fires? People present rule out CO2.
- What does the room hold? Servers, oil, fryers and batteries each need a different agent.
- Can the room hold gas? Gaps around doors, ducts and cable openings must be sealed.
- Is there space for cylinders? Inert gas needs more cylinders than halocarbons, and aerosol needs none.
Brands and approvals
We supply and install Ansul, Rotarex, Siemens, Safepro and Swastik. Examples are the Ansul R-102 kitchen system, Rotarex FireDETEC tube units and the Siemens Sinorix gas range.
Essatech supplies FM Approved and UL listed systems and components. Approvals belong to specific models, so we share the FM or UL listing for the exact model we quote, and match the approval your insurer or consultant specifies.
Fire suppression across Hyderabad
IT corridor data rooms in Gachibowli, Hitech City and the Financial District form our largest group of jobs, mostly clean agent and inert gas with aspirating detection. Our server room fire suppression page explains that work.
Pharma and industrial units in Patancheru and Jeedimetla add DG rooms and panels. Hotels and kitchens in Banjara Hills and Jubilee Hills take wet chemical hoods. Sites near Shamshabad airport add switch rooms, where our electrical fire suppression work applies.
Areas we serve. Not sure we cover your area? Call the office and ask.
- Gachibowli
- Hitech City
- Financial District
- Patancheru
- Jeedimetla
- Banjara Hills
- Jubilee Hills
- Shamshabad
Standards and approvals
Clean agent systems follow NFPA 2001 and ISO 14520, CO2 follows NFPA 12 and IS 6382, aerosol follows NFPA 2010 and kitchen hoods follow UL 300 and NFPA 17A. Buildings are planned to NBC 2016 Part 4. The Telangana State Disaster Response & Fire Services Department issues the NOC and inspects. Essatech prepares drawings and records and does not issue or promise approval. Our fire NOC consultant page explains the steps.
How the work runs
- Send drawingsShare plans, room sizes and a note of what each room holds and who works in it.
- Survey and designOur engineers visit, check room sealing and cylinder space, then choose the system.
- ProposalYou receive layouts, an equipment list and the listing for each quoted model.
- InstallationOur own team fits detection, pipes or tubes, nozzles and controls, area by area.
- Test and hand overWe test alarms, release and interlocks with you present.
Brands we supply
- Brand
- Ansul
- How we work with it
- We supply and install this brand
- Brand
- Rotarex
- How we work with it
- We supply and install this brand
- Brand
- Siemens
- How we work with it
- We supply and install this brand
- Brand
- Safepro
- How we work with it
- We supply and install this brand
- Brand
- Swastik
- How we work with it
- We supply and install this brand
What to send us
- Plans or sketches of the rooms to protect
- Room sizes and ceiling heights
- What each room holds and whether people work in it
- Make and model of your fire alarm panel