This page is part of our fire suppression system in Hyderabad range. Water ruins a server room faster than a small fire would. An FM200 gas suppression system in Hyderabad puts the fire out with a gas that leaves cables, drives and paper dry and clean. Staff can work in these rooms, because the system warns them before it discharges.
What FM200 is
FM200 is the trade name for HFC-227ea, a halocarbon clean agent. It is stored as a liquid in steel cylinders, charged with nitrogen, and turns to gas as it leaves the nozzles. It absorbs heat from the flame and interrupts the burning reaction.
The gas does not conduct electricity and leaves nothing to wipe off. NFPA 2001 and ISO 14520 are the usual design references. If you are weighing it against FK-5-1-12, our FM200 vs Novec 1230 guide sets out the differences.
How the system works
Smoke detectors in two zones sense a fire. When the second zone confirms, the panel starts a pre-discharge alarm and a short delay. The cylinders then discharge through nozzles in about ten seconds.
The gas holds in the room for a set soak period, which stops the fire from restarting. Staff can reset the room after a short clean-up.
Parts of an FM200 installation
Every system we fit has the same working parts:
- Cylinders with valves and pressure gauges
- Piping and nozzles placed to mix the gas evenly
- Smoke detection in two zones
- Release panel with manual release and an abort switch
- Hooters, strobes and a gas released sign outside the door
- Dampers that seal the room on alarm
Why the room matters
A gas system only works if the room can hold the gas. Gaps around doors, cable openings and ducts let the agent leak out, and the fire may restart. We check the room, seal what is needed and fit dampers that close on alarm.
A room integrity test at handover shows how long the gas will hold. A pressure relief vent protects walls and doors from the sudden rise in pressure when the gas enters.
Safety and the environment
At design concentration the agent is below its no observed adverse effect level, so it is used in occupied rooms. The alarm, delay and abort switch give people time to leave.
HFC-227ea has a high global warming potential, and HFCs are being phased down under the Kigali Amendment, which India has ratified. For a low warming agent, see our clean agent and inert gas pages.
Where it is used
FM200 suits rooms with valuable equipment or records:
- Server and network rooms, covered in our server room fire suppression page
- Control rooms and telecom exchanges
- Archives, libraries and record rooms
- Electrical, UPS and laboratory rooms
Brands and approvals
We supply and install Ansul, Rotarex, Siemens, Safepro and Swastik for every FM200 gas suppression system in Hyderabad, such as the Siemens Sinorix range.
Essatech supplies FM Approved and UL listed systems and components. Approvals belong to specific models, so we share the FM or UL listing for the exact model we quote, and match the approval your insurer or consultant specifies.
FM200 systems across Hyderabad
Data rooms and network rooms in Gachibowli, Hitech City and the Financial District are the most common jobs. Banks and offices in Begumpet and Secunderabad protect record rooms and server rooms.
Hospitals in Banjara Hills protect IT and record rooms, and plants at Patancheru protect control rooms. The Telangana State Disaster Response & Fire Services Department inspects the finished work. Our Gachibowli team handles each FM200 gas suppression system in Hyderabad, and the Hyderabad office page lists our other services. Coastal sites can read our FM200 Gas Suppression System in Visakhapatnam page.
Areas we serve. Not sure we cover your area? Call the office and ask.
- Gachibowli
- Hitech City
- Financial District
- Begumpet
- Secunderabad
- Banjara Hills
- Patancheru
Standards and approvals
We design to NBC 2016 Part 4, with NFPA 2001 and ISO 14520 as the references for clean agent systems. The fire department decides what each building needs, and Essatech does not issue or promise approval. Our fire NOC consultant page explains the usual steps. These rules hold for every FM200 gas suppression system in Hyderabad that we plan.
How the work runs
- Send drawingsShare floor plans, room sizes and a note of what each room holds.
- Survey and designOur engineers visit the site, check the room for gaps and draft the design.
- ProposalYou receive layouts, an equipment list and the listing for each model.
- InstallationOur own team fits cylinders, pipes, detection and controls.
- Test and hand overWe run alarm, release and integrity tests with you present.
Brands we supply
- Brand
- Siemens
- How we work with it
- We supply and install this brand
- Brand
- Rotarex
- How we work with it
- We supply and install this brand
- Brand
- Ansul
- How we work with it
- We supply and install this brand
- Brand
- Safepro
- How we work with it
- We supply and install this brand
- Brand
- Swastik
- How we work with it
- We supply and install this brand
What to send us
- Room dimensions and ceiling height
- What the room holds and whether people work in it
- Doors, ducts and cable openings
- Fire alarm panel make and model